5% and 75%. Triplicates of the solvent systems were prepared in glass vials, excess MPTS was added to the solutions and the vials were sealed to eliminate the possibility of evaporation. The samples were then vortexed (Heidolph Multi Reax, Heidolph Instruments, and Cinnaminson, NJ, USA) for 20 min and left to equilibrate at room temperature. After equilibration (determined as 1 week) an aliquot of the samples was centrifuged (Galaxy 20R, VWR International, Suwanee, GA, USA) at 5000 rpm for 5 min to ensure sedimentation http://www.selleckchem.com/products/XAV-939.html of the excess MPTS and the drug content of the saturated solution was measured using a GC–MS method detailed in Section 2.4. Prior to GC–MS

measurements the internal standard (1 mg/ml of dibuthyl disulfide; DBDS) was added to the samples and dilution with ethanol and cylcohexanone was performed. A GC–MS method was chosen for the quantitative determination of MPTS. The system consisting of an Agilent Technologies 7890A GC with a 7683 autosampler and a 5975C VL MSD, triple-Axis detector (Agilent Technologies, Santa Clara, CA, USA). A DB-5MS column (30 m × 0.25 mm

ID, 0.25 μm film thickness; Agilent Technologies, Santa Clara, CA, USA) was used with He carrier gas at a flow rate of 1 ml/min and pressure of 7.6522 psi. The conditions for GC and MS are detailed in Table 1 and Table 2. Dielectric constant measurements were performed using a HP4285A LCR meter. The AC signal amplitude for the impedance measurement was 100 mV, and the applied frequency PD0332991 ranged from 75 kHz to 30,000 kHz in logarithmic distribution. All measurements were carried out at 20 ± 1 °C in a thermostatable cylindrical cell (originally prepared for a Radelkis OH-301 type dielectrometer) using an interface. Cyclohexane and ethanol were used as reference for determining the capacitances of the applied empty cell. The dielectric constant results are presented as values measured at 3022.2 kHz. LD50 studies were conducted using the Dixon up-and-down method with 1.0 mg/ml and 3.5 mg/ml KCN solutions, a 50 mg/ml MPTS stock solution,

and a 100 mg/ml TS solution. Male CD-1 mice (Charles River Breeding Laboratories, Inc., Wilmington, MA) weighing 18–28 g were housed of at 21 °C and in light-controlled rooms (12-h light/dark, full-spectrum lighting cycle with no twilight), and were furnished with water and 4% Rodent Chow (Teklad HSD, Inc., CITY, WI) ad libitum. All animal procedures were conducted in accordance with the guidelines by “The Guide for the Care and Use of Laboratory Animals” (National Academic Press, 2010), accredited by AAALAC (American Association for the Assessment and Accreditation of Laboratory Animal Care, International). At the termination of the experiments, surviving animals were euthanized in accordance with the 1986 report of the AVMA Panel of Euthansia.

Leave a Reply

Your email address will not be published. Required fields are marked *

*

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>